false
Catalog
LQCL2302 - CMLE - Falsely Elevated Troponin Result ...
Falsely Elevated Troponin Results
Falsely Elevated Troponin Results
Back to course
Pdf Summary
The document discusses a case involving a 35-year-old man with elevated cardiac troponin levels but no acute myocardial infarction. The aim is to investigate the cause of the discrepancy between the clinical and laboratory findings, with a focus on immunoassay interferences. Several possible interferences are highlighted, including hemolysis, icterus, interfering antibodies, and macroproteins. Techniques like protein precipitation or gel filtration chromatography can help to identify and investigate macroprotein interference. The importance of interpreting troponin results accurately for diagnosing myocardial infarction is emphasized, with considerations for chronic elevations unrelated to acute events. The case study demonstrated the need for a systematic approach to investigate and resolve issues with troponin assays, ultimately highlighting the significance of accurate laboratory testing for patient care.
Keywords
cardiac troponin levels
acute myocardial infarction
immunoassay interferences
hemolysis
icterus
interfering antibodies
macroproteins
protein precipitation
gel filtration chromatography
troponin assays
×
Please select your language